1.
Braz. dent. j ; 23(5): 484-489, Sept.-Oct. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-660348

ABSTRACT

This in vitro study analyzed the effect of different load application devices on fracture resistance and failure mode of maxillary premolars restored with composite resin. Sixty human maxillary premolars received standardized mesio-occluso-distal cavity preparations and were restored with composite resin. The specimens were randomly divided into 6 groups (n=10). Compressive loading was applied using 6 different metallic devices: S2: 2-mm sphere; S6: 6-mm sphere; C2: 2-mm cylinder; C6: 6-mm cylinder; WS: wedge shape device; and MAT: individualized metallic antagonist tooth. Data were analyzed statistically using one-way ANOVA and Tukey's test (α=0.05). The failure mode was recorded based on the 4 sequential levels. Statistical analysis revealed that WS presented significantly higher fracture resistance than S6 and C6. No significant difference was found among MAT, C2, S2 and S6. Sphere and cylinder with 6 mm were similar, with the lowest values of all groups. MAT presented the least number of catastrophic failures while C2, S2 and WS presented the highest. The type of load application device influences significantly the behavior of the teeth-restoration complex during mechanical fracture resistance test.


Este estudo avaliou o efeito de diferentes tipos de dispositivos de aplicação de carga na resistência à fratura de pré-molares superiores restaurados com resina composta. Sessenta pré-molares humanos receberam preparo mésio-ocluso-distal padronizado e as cavidades foram restauradas com resina composta. As amostras foram aleatoriamente divididas em 6 grupos (n=10). Carregamento de compressão foi realizado usando seis diferentes dispositivos metálicos de aplicação de carga: S2 e S6: esfera de 2 mm e 6 mm de diâmetro respectivamente; C2 e C6: cilindro de 2 mm e 6 mm de diâmetro respectivamente; WS: lâmina de faca e MAT: antagonista individualizado em metal. Os resultados foram submetidos à análise de variância e teste de Tukey (p<0,05). O modo de falha foi classificado em 4 níveis e estão apresentado em porcentagem. O dispositivo WS resultou em maior resistência a fratura de pré-molares que S6 e C6. Não houve diferença estatística entre os grupos MAT, C2, S2 e S6. Menor resistência foi verificada com o uso de S6 e C6. O dispositivo MAT resultou em menor número de falhas catastróficas enquanto nos grupos C2, S2 e WS essas falhas foram significativas. O tipo de dispositivo de aplicação de carga influenciou significativamente no comportamento do complexo dente-restauração durante o teste de resistência à fratura.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent , Equipment Failure Analysis/instrumentation , Materials Testing/instrumentation , Tooth Fractures , Analysis of Variance , Bicuspid , Equipment Failure Analysis/methods
2.
Rev. bras. eng. biomed ; 28(2): 179-189, jun. 2012. tab
Article in Portuguese | LILACS | ID: lil-649104

ABSTRACT

Esta pesquisa objetiva recomendar especificações que os analisadores de desfibriladores e cardioversores devam apresentar, tais como: erro máximo de medição, resolução, condições de operação e recursos desejáveis. As recomendações apresentadas baseiam-se nos quesitos demandados para a realização dos ensaios previstos pelas normas NBR IEC  60601-2-4:2005 e ANSI/AAMI  DF80:2003. Uma avaliação das especificações fornecidas de quatro analisadores importados (Fluke  QED6, Fluke Impulse  7000, MTK-Biomed  Delta 3000  MKII e NETECH Delta  3000) e dois analisadores nacionais (Transmai  JM-01 e Ourox  JAU-100) também foi realizada, tendo encontrado diversas falhas de especificações em todos os analisadores. Estas falhas vão desde o não fornecimento de dados a condições aquém das desejáveis para um analisador de desfibriladores e cardioversores. Os problemas mais graves encontrados estão relacionados à não apresentação de especificações tais como precisão, exatidão de medição, erro máximo de medição ou outra informação que por sua vez auxiliaria na determinação do intervalo de abrangência para a medida, como a de energia pelo analisador Transmai  JM-01, algo inaceitável para um instrumento de medição, incertezas elevadas e condições de operação aquém das necessárias para a realização dos ensaios determinados pelas normas NBR IEC  60601-2-4:2005 e ANSI/AAMI  DF80:2003.


This study aims to recommend specifications for defibrillator and cardioverter analyzers, such as maximum permissible measurement error, resolution, operating conditions and desirable features. The recommendations are based on the test requirements from the ABNT  NBR IEC  60601-2-4:2005 and ANSI/AAMI  DF80:2003 standards. An evaluation of the specifications provided by four imported analyzers (Fluke QED 6, Fluke Impulse  7000, MTK-Biomed  Delta 3000  MKII and NETECH Delta  3000) and two Brazilian analyzers (Transmai  JM-01 and Ourox  JAU-110) has also been performed, and several problems were found with specifications of those analyzers. These problems range from unsupplied data to less than desirable conditions for a defibrillator and cardioverter analyzer. The most serious problems encountered are related to the lack of specifications such as precision, accuracy, maximum permissible measurement error or other specifications that would help determine the coverage interval of the measure, an unacceptable  mistake for a measurement instrument. Other problems were related to measurement error and operating conditions not complying with the requirements of the ABNT  NBR IEC  60601-2-4:2005 and the ANSI/AAMI  DF80:2003 standards.


Subject(s)
Electric Countershock/standards , Defibrillators/standards , Equipment and Supplies, Hospital/standards , Equipment Safety/instrumentation , Equipment Safety/methods , Equipment Safety/standards , Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/standards , Quality Control , Equipment Failure , Reference Standards
3.
Rev. colomb. biotecnol ; 13(2): 70-83, dic 1, 2011. tab, graf
Article in Spanish | LILACS | ID: lil-645169

ABSTRACT

Desde los años sesenta se utilizan las señales electromoigráficas (EMG) como señales de control para prótesis actuadas por servomotores, así como en la estimulación de músculos que sufren de parálisis o de atrofia parcial. Mediante el avance tecnológico se ha logrado mejorar el diseño, así como la fabricación de sistemas protésicos, que funcionan como extensiones de algún miembro del cuerpo humano, agregando además con los nuevos diseños, características básicas como: flexibilidad, estética morfológica, incremento de la relación resistencia/peso así como multifuncionalidad. Una prótesis mioeléctrica es una estructura desarrollada con el fin de reemplazar una parte o la totalidad de un miembro del cuerpo humano, lo mismo que suplir las funciones perdidas de este, sin dejar de lado la imagen corporal del paciente. Estas prótesis son accionadas por actuadores que se controlan a través de señales EMG, las cuales se obtiene mediante agujas intramusculares superficiales o por medio de electrodos colocados en el muñón del paciente. Este tipo de prótesis es cada vez más aceptado por personas con amputación de mano, ya que proporciona un mejor desempeño y permite el incremento de funcionalidad para el paciente que la utiliza, debido a que su control es más sencillo.


Since 60’s electromiographical signals (EMG’s) are used like a control signals for prostheses acted by servomotors, as well as stimulation of muscles that are affected due to partial or total paralysis. By means of technological advance, it has been possible to improve the design as well as the production of prosthetic systems that work as extensions of some member of human body, adding with the new designs also basic characteristics as: flexibility, aesthetic morphology, and superior strength/weight relationship, as well as multi-functionality. Mioelectric prosthesis is a structure developed with the purpose of replacing a part or the entirety member of human body, same as to replace the lost functions of this, without leaving aside patient's corporal image. These prostheses are acted by actuators that are controlled through EMG signals, which are obtained by means of intramuscular or superficial needles, or by means of electrodes placed in patient's stump. This class of prostheses is more and more accepted by people with hand amputation since it provides a better acting, that which allows a superior functionality for patient that uses it, because its control is simpler.


Subject(s)
Prosthesis Design/adverse effects , Prosthesis Design/methods , Prosthesis Design/mortality , Prosthesis Design/standards , Equipment Failure Analysis/statistics & numerical data , Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards
4.
Rev. bras. eng. biomed ; 26(1): 11-24, abr. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-570335

ABSTRACT

Este trabalho teve por objetivo o desenvolvimento e avaliação da eficácia de um protocolo de controle de qualidade de imagens geradas por equipamentos de ultrassom operando no modo B, que fosse de fácil implementação e que utilizasse um único objeto de testes. O protocolo proposto foi avaliado em 25 equipamentos de ultrassom utilizados em medicina obstétrica, ginecologia e clínica médica, selecionados em várias clínicas e hospitais de Curitiba, Brasil. Somente modelos de equipamentos que suportavam os três tipos padrões de transdutores (convexo, linear e endocavitário) foram incluídos nos testes. No entanto, em alguns dos equipamentos, nem todos os transdutores estavam disponíveis, totalizando 72 transdutores avaliados durante os testes. Um objeto de testes de uso geral foi utilizado para avaliar os seguintes parâmetros: resoluções laterais e axiais, profundidade de visualização e exatidão das distâncias medidas, entre outras. O protocolo foi implementado em duas partes: uma envolvendo a inspeção física do equipamento/monitor e outra para avaliação dos transdutores. Entre os resultados obtidos, pode-se destacar a efetividade e simplicidade do protocolo proposto, o qual é completamente baseado em um único objeto de testes. Considerando as normas e relatórios técnicos utilizados, para aproximadamente 86% dos transdutores avaliados, falhas foram detectadas em um ou mais indicadores de qualidade de imagem. Os resultados obtidos estão de acordo com outros estudos realizados no Brasil, mostrando que um grande número de equipamentos utilizados diariamente em clínicas e hospitais apresenta um ou mais parâmetros fora dos limites estabelecidos em normas técnicas, tornando difícil o diagnóstico médico e, consequentemente, submetendo o paciente a riscos.


This study aims the development of a quality control protocol of images generated by B-mode ultrasound equipment, being of simple implementation and making use of a single phantom, as well as the evaluation of the proposed protocol effectiveness. The proposed protocol was evaluated on 25 ultrasound equipment used in obstetric medicine, gynaecology and medical clinic, selected from several clinics and hospitals of Curitiba, Brazil. Only systems with three standard transducers (convex, linear and endocavitary types) should be selected, however for some units not all of them were available, thus a total of 72 transducers were tested. A general purpose phantom was used to evaluate the following parameters: lateral and axial resolution, deepness of visualization and accuracy between distances, among others. The protocol was implemented in two parts: one involving the physical inspection of the equipment/monitor and another for the transducers evaluation. Among the results obtained, one is highlighted by the effectiveness and simplicity of the proposed protocol, which is completely based on a single phantom. Considering the utilized standards and technical reports, for approximately 86% of the evaluated transducers, some kind of failure or problem was detected in one or more image quality indicators. The results, inaccordance to those obtained by other authors in Brazil, showed that agreat number of equipment used daily in clinics and hospitals present one or more parameters out of the standards, making the medical diagnosis difficult and consequently submitting the patient to risks.


Subject(s)
Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards , Diagnostic Techniques, Obstetrical and Gynecological/instrumentation , Diagnostic Techniques, Obstetrical and Gynecological/standards , Ultrasonography/instrumentation , Ultrasonography/standards , Quality Control , Equipment and Supplies, Hospital/standards , Diagnostic Errors/prevention & control , Equipment Failure , Reference Standards , Equipment Safety/instrumentation , Transducers/standards
5.
Yonsei Medical Journal ; : 473-478, 2003.
Article in English | WPRIM | ID: wpr-105368

ABSTRACT

The aim of this study was to compare the accuracy of four different methods for measuring wear using an apparatus that simulates known amounts of three dimensional wear. Wear was measured using the manual methods reported by Charnley, Livermore, Dorr and Wan and the computerized method reported by Devane. Only the method reported by Devane measured the three-dimensional (superior and anterior) wear with a reasonable accuracy, with a mean measurement error of 0.21 mm. With superior wear alone, Charnley's method underestimated the extent of wear by 16.6%, with a mean error of 0.35 mm; Livermore's method estimated wear to within 9.5%, with a mean error of 0.16 mm; Devane's method estimated wear to within 9.5%, with a mean error of 0.15 mm; and Dorr's method underestimated wear by 25.4%, with a mean error of 0.56 mm. Dorr's method was modified as a result of the experimental tests. The clinical application of the new method showed comparable data to that using the Devane method. In conclusion, this new method can be used to estimate the average wear in groups of patients accurately.


Subject(s)
Humans , Equipment Failure Analysis/instrumentation , Hip Prosthesis , Polyethylene , Prosthesis Failure , Stress, Mechanical
6.
Rev. bras. eng. biomed ; 18(3): 151-162, set.-dez. 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-358861

ABSTRACT

A incubadora neonatal é um equipamento médico-assistencial usado para a manutenção da vida de recém-nascidos prematuros. Sua função é proporcionar um ambiente termoneutro que é obtido através do controle da temperatura e da umidade relativa do ar em níveis adequados. Isto permite que o bebê mantenha a temperatura corporal normal a baixas taxas metabólicas. Este ambiente contibui para um desenvolvimento rápido e com uma menor incidência de doenças. No presente trabalho, descreve-se um aparelho eletrônico constuído para testar incubadoras, que verifica as características do ambiente por elas proporcionado ao recém-nascido. O protótipo desenvolvido mede, no interior da incubadora, a temperatura do ar em cinco pontos diferentes, a umidade relativa, o nível sonoro e verifica o estado da velocidade do fluxo de ar. O equipamento pode funcionar no modo de coleta, onde armazena as grandezas citadas a cada minuto, permitindo uma transferência posterior dos dados para um microcomputador PC, ou no modo de teste, onde realiza testes baseados na norma NBR IEC 601-2-19. Neste último, o aparelho instrui o operador através de mensagens no visor e avisos sonoros quando ajustes devem ser feitos nos controles da incubadora, ou quando algum problema é detectado. Os resultados de testes realizados no modo de coleta, em algumas incubadoras, são apresentados.


Subject(s)
Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/standards , Incubators, Infant , Equipment Safety/instrumentation , Risk Factors , Documentation